Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 600mm enclosures
High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, returns the warm air to the plenum and eliminates hot spots from the data center. Through automatic fan speed control based upon temperature, the fans will self-adjust for optimal performance. With a unit-mounted LCD display, users can view temperatures at the rack, monitor alarm conditions and... More Info
Our Vertical Cable management offers an ideal way to keep your cabling tidy with maximum airflow.The metal frames fit between the profile and the side of the cabinet and are only suitable for 800mm wide Floor Standing Cabinets/ Server Cabinets. They will not fit into 600mm wide cabinet.For use in 800mm Wide Cabinets Choose the size which fits exactly into Cabinet Black Finish Excellent Air flow management More Info
Rack PDU Red label kit (Quantity 10 units)
Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also... More Info
NetShelter SX, 48U, w/o Doors, Black
NetShelter SX 48U 750mm Wide x 1200mm Deep Enclosure Without Doors Black More Info
Power Cord Kit (6 ea), Locking, C19 to C20 (90 Degree), 0.6m
Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this exclusive easy-to-use cord retention method. While these cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled only when used with APC AP8000 series Rack PDUs or IT equipment with built-in locking receptacles. These locking connectors reduce the probability of accidentally disconnecting cords and dropping loads. More Info
Rack PDU 2G, Metered, ZeroU, 20A, 208V, (18) C13 & (2) C19, L620 Cord
Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local... More Info
Racky Rax Fan Trays are designed to keep networking equipment cooler by increasing airflow through the cabinet.Specially designed to fit on the roof of Racky Rax Floor cabinets, the Fan trays come complete with either two or four high quality, low noise fans; and are powered via a standard UK 240V plug.The 2 way RR-FT-2 is for use in 600 by 600 mm or 800 by 600 mm Floor Standing cabinets; the 4 way RR-FT-4 is for 600mm by 800mm or 800 by 800mm server cabinets and the Large 4 way RR-FT-14 is for 800 by 1000 mm server cabinet.Features &... More Info
Rack PDU 2G, Switched Plus, ZeroU, 30A, 200/208V, (21) C13 & (3) C19
Network Management Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up... More Info
NetShelter SX, 48U, w/o Doors, Black
NetShelter SX 48U 750mm Wide x 1200mm Deep Enclosure Without Sides Without Doors Black More Info
600x35x1915mm, 10kg, White
NetShelter SX 42U 600mm Wide Perforated Curved Door White- Rack system components that can be added to existing racks if requirements change. - Includes : Door handle , Door mounting hardware , Installation guide , Key(s) - Door ventilation exceeds 830 in2 (5355 cm2) Adequate ventilation is required for proper operation of today's servers. NetShelter Enclosures include fully perforated front and rear doors to provide ample ventilation for servers and networking equipment. The perforation pattern provides 844 square inches of open area on... More Info
RACK PDU 2G, METERED, ZEROU, 30A, 200/208V, (36) C13 & (6) C19
Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles,... More Info
513 x 376 x 2136 mm, 11.82 kg
Eliminates the pain involved in determining where to install rack-mount devices within a rack by labeling each vertical mounting rail with the actual U-height position.Stabilizations plates can either be mounted internally to conserve floor space or externally More Info