Basic Rack PDU AP9572
Rack PDU, Basic, Zero U, 16A, 208/230V, (15) C13. More Info
Rack ATS, 120V, 30A, L5-30P in, (16) 5-20R out
Provides redundant rack mount power to single-corded equipment. 10 kAIC Overcurrent Protection Provides protection in the event of a significant overcurrent event.Command line interface Offers simultaneous remote management access through Telnet and SSH.Current Monitoring Monitors the aggregate current draw per power distribution unit.Cyber security A cyber-secure connection provides improved security for your infrastructure devices, and machine data forms the basis of operational insights and analytics, aimed at reducing equipment... More Info
Rack PDU, basic, vertical, 220-240V, 32A, (20) C13, (6) C19
Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard... More Info
In-Line Current Meter, 32A, 230V, IEC309-32A 3-PH, 3P+N+G
Metered rack Power Distribution Units (PDUs) provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur. More Info
2U, 30A, 208V, 12x C13s, 4x C19, NEMA L6-30P, 444 x 112 x 88 mm, 3360 g
AvailabilityAlarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Local Current Monitoring Display The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum... More Info
208V, 50/60Hz, 35A, 12.5kVA, 0U, 56 x 89 x 1778mm, 8.08kg, Black
Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Power DelaysAllows users to configure the sequence in which power is turned on or off... More Info
Rack PDU Blue label kit (Quantity 10 units)
Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also... More Info
Rack PDU Red label kit (Quantity 10 units)
Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also... More Info
Rack PDU 2G, Switched Plus, ZeroU, 30A, 200/208V, (21) C13 & (3) C19
Network Management Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up... More Info
Rack PDU 2G, Metered, ZeroU, 17.2kW, 208V, (6) C13 & (12) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC... More Info
Rack PDU 9000 Switched, ZeroU, 30A, 200/208V, (21) C13/C15 & (3) C19/C21
Field-replaceable NMCIntegrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.High Retention OutletsWith no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.60C Operating TemperatureSelect 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in... More Info
Rack PDU 9000 Switched, ZeroU, 32A, 230V, (21) C13 & (3) C19
NetShelter Switched Rack PDUs Features & Benefits Manageability 1% Metering Accuracy Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs. Gigabit Ethernet Connectivity 9000 series PDUs provide Gigabit Ethernet to enhance and standardize... More Info